Репозиторий Dspace

THE EFFICIENCY DEPENDANCE OF A SINGLE-CIRCUIT POWER UNIT WITH A HELIUM-COOLED REACTOR AND A HYDROGEN MODULE ON THE DEGREE OF REGENERATION

Показать сокращенную информацию

dc.contributor.author Nurym, K.A.
dc.contributor.author Antonova, A.M.
dc.contributor.author Sakipov, K.E.
dc.contributor.author Vorobyev, A.V.
dc.contributor.author Stetsov, N.V.
dc.date.accessioned 2025-12-29T09:03:56Z
dc.date.available 2025-12-29T09:03:56Z
dc.date.issued 2025
dc.identifier.issn 1811-1165
dc.identifier.other doi.org/10.31489/2025N1/52-58
dc.identifier.uri http://repository.enu.kz/handle/enu/29134
dc.description.abstract The most attractive single-circuit scheme of the power unit was chosen. Helium at the outlet of the reactor core enters the steam generator, where it gives part of the heat to generate highly superheated steam for the electrolysis plant. Next, helium operates in a closed gas turbine cycle with heat recovery. A gas-cooled reactor with a turbine and compressor allows the use of a thermodynamic cycle with high efficiency. A series of design calculations of the regenerator for various degrees of regeneration have been performed. A series of assessments of the effect on the real resistance of the regenerator from the high- and low-pressure sides have been carried out. The thermal scheme of energy production is calculated in accordance with a series of design calculations of the regenerator. ru
dc.language.iso en ru
dc.publisher Eurasian Physical Technical Journal ru
dc.relation.ispartofseries 22, 1(51);
dc.subject reactor ru
dc.subject helium ru
dc.subject gas-turbine installation ru
dc.subject regenerator ru
dc.subject hydraulic resistance ru
dc.subject aerodynamics resistance ru
dc.title THE EFFICIENCY DEPENDANCE OF A SINGLE-CIRCUIT POWER UNIT WITH A HELIUM-COOLED REACTOR AND A HYDROGEN MODULE ON THE DEGREE OF REGENERATION ru
dc.type Article ru