dc.description.abstractThe article presents the results of vertical static load tests of diametral and deep bored piles specially conducted at the construction site of EXPO-2017 in Astana, Kazakhstan. The methodology for determining the bearing capacity of the pile is summarized. Bored piles with a length of 31.5 m and a diameter of 1000 mm were tested. Vertical static load tests were conducted for the following load configurations: Bidirectional Static Loading Test (according to ASTM D8169), Static Compression Loading Test according to ASTM D1143-07 and Static Loading Test according to GOST 5686-12. The method presented in the paper can serve as practical guidelines to assess the capacities of bored piles installed in the field. This geotechnical investigation is important for understanding the soil-structures interaction on difficult soil ground conditions related to the construction sites.ru