REPOSITORY.ENU

IDENTIFICATION OF CHARACTERISTICS OF CONCEPTUAL PROTOTYPE OF MICROPROCESSOR RESOURCE-SAVING RELAY PROTECTION SYSTEM

Показать сокращенную информацию

dc.contributor.author Neftissov, A.
dc.contributor.author Kazambayev, I.
dc.contributor.author Kirichenko, L.
dc.contributor.author Urazayev, D.
dc.contributor.author Biloshchytskyi, A.
dc.contributor.author Abdirashev, O.
dc.date.accessioned 2025-12-25T10:20:49Z
dc.date.available 2025-12-25T10:20:49Z
dc.date.issued 2024
dc.identifier.citation Neftissov, A., Kazambayev, I., Kirichenko, L., Urazayev, D., Biloshchytskyi, A., Abdirashev, O. (2024). Identification of characteristics of conceptual prototype of microprocessor resource-saving relay protection system. Eastern-European Journal of Enterprise Technologies, 5 (5 (131)), 60–69. https://doi.org/10.15587/1729-4061.2024.312489 ru
dc.identifier.issn 1729-3774
dc.identifier.other doi.org/10.15587/1729-4061.2024.312489
dc.identifier.uri http://repository.enu.kz/handle/enu/29095
dc.description.abstract The object of the study is the conceptual prototype of a microprocessor resource-saving relay protection system. Currently, relay protection ensures electrical networks reliable and efficient work, however, the traditional architecture is proprietary, not allowing to fix and replace damaged parts without a company specialist. Therefore, the open-architecture relay protection is a very pressing issue, but the problem lies in meeting the relay protection requirements. The data transmission protocols nRF and ESP-NOW, Hall sensors evaluation for AC current measurement determination and sensor accuracy improvement was implemented. Experimental validation demonstrated that nRF and ESP-NOW protocols meet the delay and reliability requirements, however, the nRF protocol is more suitable due to its flexibility and obstacle penetration. The data demonstrated that the most effective conditions are without obstacles at 15 meters from the modem and with obstacles 5 meters from the modem. The experiment of Hall sensors characteristics determination demonstrated the accuracy of current measurement with the set values of the opening and closing currents. Nevertheless, it is not accurate (12.45 %) for the relay protection application. Therefore, the application of the changing values of the opening and closing currents is more effective and accuracy reaches 6.92 %. As a result, the service life of the Hall sensor was determined, and even after 10 million openings, the open state time remained unchanged. Therefore, the approximation function for current amplitude determination depending on open state time was found. On the other hand, Hall sensors may suffer from temperature drift and require further optimization to be fully reliable. The study limitation is the current range from 0 to 800 A ru
dc.language.iso en ru
dc.publisher astern-European Journal of Enterprise Technologies ru
dc.relation.ispartofseries 5 (5 (131)), 60–69;
dc.subject relay protection ru
dc.subject reed switch ru
dc.subject Hall sensor ru
dc.subject magnetic field ru
dc.subject open architecture ru
dc.title IDENTIFICATION OF CHARACTERISTICS OF CONCEPTUAL PROTOTYPE OF MICROPROCESSOR RESOURCE-SAVING RELAY PROTECTION SYSTEM ru
dc.type Article ru


Файлы в этом документе

Данный элемент включен в следующие коллекции

Показать сокращенную информацию

Поиск в DSpace


Просмотр

Моя учетная запись