REPOSITORY.ENU

Design of Conical Foundations with Increased Bearing Capacity in Areas of Undermined Soils

Показать сокращенную информацию

dc.contributor.author Zhussupbekov, Askar
dc.contributor.author Sarsembayeva, Assel
dc.contributor.author Bazarov, Baurzhan
dc.contributor.author Omarov, Abdulla
dc.date.accessioned 2026-03-13T11:39:08Z
dc.date.available 2026-03-13T11:39:08Z
dc.date.issued 2024
dc.identifier.citation Zhussupbekov, A.; Sarsembayeva, A.; Bazarov, B.; Omarov, A. Design of Conical Foundations with Increased Bearing Capacity in Areas of Undermined Soils. Appl. Sci. 2024, 14, 1816. https://doi.org/10.3390/ app14051816 ru
dc.identifier.issn 2076-3417
dc.identifier.other doi.org/10.3390/ app14051816
dc.identifier.uri http://repository.enu.kz/handle/enu/30343
dc.description.abstract This article discusses the foundations of a conical shape directed with their apex downwards to increase the cross-sectional area and, accordingly, the bearing capacity during settlement and under the influence of horizontal tensile strains in undermined areas. To simulate the deformability of undermined and seismically exposed foundations, a three-dimensional expandable box was manufactured and assembled. Models of a conical foundation with an aperture angle of the cones at 90◦ and 80◦ were buried into the soil at 0.75 of its height, in order to provide a safety margin for further loading due to an increase in the bearing area when the cone is immersed deeper into the ground. Laboratory and field tests were performed on the vertical loading of single cones before and after horizontal soil displacement. Numerical modeling of the interaction between soil and foundation was carried out for conical foundation models that were considered for laboratory and field testing using the Plaxis 2D (Version 8.2) program. To compare the bearing capacity, isolated shallow foundations with a diameter equal to the cross section of the conical foundation at the intersection with the ground surface were tested. The isolated shallow foundations lost their bearing capacity after 0.15 kN in laboratory tests and after 75 kN in the field tests, while the ultimate bearing capacity of conical foundations with the similar cross section at the soil surface was not achieved, even after 0.2 kN during laboratory tests with horizontal soil displacement and at a load of 100 kN in field tests. ru
dc.language.iso en ru
dc.publisher Applied Sciences ru
dc.relation.ispartofseries 14, 1816;
dc.subject conical foundations ru
dc.subject horizontal displacement of soils ru
dc.subject load–settlement interaction ru
dc.subject stable foundations ru
dc.subject undermined soils ru
dc.title Design of Conical Foundations with Increased Bearing Capacity in Areas of Undermined Soils ru