Proton beam energy calibration of the 3 MV Tandetron™ at IFIN-HH

Thumbnail
Автор
Testov, D.A.
Straticiuc, M.
Söderström, P.-A.
Aogaki, S.
Andrei, R.-F.
Azhibekov, A.K.
Balabanski, D.L.
Ban, S-R.
Brezeanu, M.
Burducea, I.
Constantin, P.
Dhal, A.
Djourelov, N.
Florea, N.
Gavrilescu, A.
Guardo, L.
Iancu, D.
Ioannidis, S.
Kahl, D.
Kuncser, I.
Kurmanaliyev, Zh.
Kusoglu, A.
Lorusso, G.
Mauyey, B.
Morzabayev, A.
Nedelcu, C.V.
Nichita, D.
S., Niculae
Parlea, P.
Paun, C.
Petruse, T.
Rotaru, A.
Roy, R.
Spataru, A.
State, A.N.
Toma, V.
Tozar, T.
Vasilca, V.
Дата
2025
Редактор
Journal of Instrumentation
ISSN
1748-0221
Аннотации
The ELIGANT-TN long neutron counter, the ELISSA silicon strip array and the Mini-eTPC active gas target detector all represent nuclear physics research tools constructed at Extreme Light Infrastructure - Nuclear Physics (ELI-NP) for use in 𝛾-beam experiments. Currently, these three setups are used at the charged particle accelerators of the “Horia Hulubei” National Institute for R&D in Physics and Nuclear Engineering (IFIN-HH), for performing reaction cross-section measurements. Accurate knowledge of the incident beam energy is of paramount importance for such studies, which is why in the present article we report on a new proton beam energy calibration performed using the following threshold reactions: 7Li(𝑝, 𝑛) 7Be, 13C(𝑝, 𝑛) 13N and 51V(𝑝, 𝑛) 51Cr. The measurements were performed by varying the projectile energy across the key range of ∼ 1600–3200 keV. The results demonstrate a linear dependence of the projectile energy on the terminal voltage.
URI
http://repository.enu.kz/handle/enu/30924
Открыть
Proton beam energy calibration of the 3 MV.pdf (1.189Mb)
Collections
  • Physics and Astronomy[794]
Показать полную информацию
CORE Recommender

Евразийский национальный университет имени Л.Н. Гумилева | Научная библиотека | Контакты
Яндекс.Метрика
Научная библиотека | Контакты
 

Просмотр

Весь DSpaceСообщества и коллекцииДата публикацииАвторыНазванияТематикаЭта коллекцияДата публикацииАвторыНазванияТематика

Моя учетная запись

ВойтиРегистрация

Евразийский национальный университет имени Л.Н. Гумилева | Научная библиотека | Контакты
Яндекс.Метрика
Научная библиотека | Контакты